logo
Dom > produkty > Przepływomierz ultradźwiękowy >
Proline Prosonic Flow G 500 ultrasonic flowmeter

Proline Prosonic Flow G 500 ultrasonic flowmeter

Proline Prosonic ultrasonic flowmeter

ultrasonic flow meter with warranty

Prosonic Flow G 500 meter

Miejsce pochodzenia:

Szwajcaria

Nazwa handlowa:

Endress+Hauser

Orzecznictwo:

CE

Numer modelu:

Proline Prosonic Flow G 500

Skontaktuj się z nami
Poproś o wycenę
Szczegóły produktu
Zakres pomiarowy:
Gaz: 0,3 m/s do 40 m/s
Max. Maks. process pressure ciśnienie procesowe:
0,7 do 101 bar a (10,15 do 1464,88 psi a)
Średni zakres temperatur:
-50 do 150°C (-58 do +302°F)
Zakres temperatur otoczenia:
-40 do 60°C (-40 do +140°F)
Materiał obudowy czujnika:
Stal nierdzewna, 1.4404(316/316L), 1.4408/1.4409 (CF3M)
Materiał obudowy przetwornika:
lSi10Mg, powlekany; 1.4409 (CF3M) podobny do 316L
Podkreślić:

Proline Prosonic ultrasonic flowmeter

,

ultrasonic flow meter with warranty

,

Prosonic Flow G 500 meter

Warunki płatności i wysyłki
Minimalne zamówienie
1 szt
Szczegóły pakowania
Każde urządzenie ma indywidualne pudełko, a wszystkie pola są pakowane w standardowe pakiety lub dos
Czas dostawy
5-8 DNI ROBOCZYCH
Zasady płatności
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Możliwość Supply
1000 sztuk/sztuk tygodniowo do negocjacji
Opis produktu
Proline Prosonic Flow G 500 Ultrasonic Flowmeter
Highly robust gas specialist for fluctuating process conditions as remote version with up to 4 I/Os. Flexible device with user-definable gas mixtures for demanding measuring tasks.
Field of Application
For a wide range of gas applications, Prosonic Flow G provides reliable flow measurement, even with wet gas and changing gas properties and compositions. Accurate measurement of natural and process gas in the chemical, oil, and gas industries.
Key Benefits
  • Flexible device with user-definable gas mixtures for demanding measuring tasks
  • Maximum reliability even with humid or wet gas - sensor design insensitive to condensate
  • High-performance process control - real-time pressure- and temperature-compensated values
  • Efficient solution - multivariable, no pressure loss
  • Full access to process and diagnostic information - numerous, freely combinable I/Os
  • Reduced complexity and variety - freely configurable I/O functionality
  • Integrated verification - Heartbeat Technology
Measuring Principle
Ultrasonic flow measurement unaffected by gas composition
Technical Specifications
Measurement Accuracy
Measurement Type Accuracy Range Velocity Range
Volume Flow (Standard) ±1.0% to ±2% o.r. 0.3 to 40 m/s
Volume Flow (Optional Calibration) ±0.5% to ±1.0% o.r. 0.3 to 40 m/s
Corrected Volume Flow (Standard) ±1.2% to ±2.1% o.r. 0.3 to 40 m/s
Corrected Volume Flow (Optional Calibration) ±0.8% to ±1.2% o.r. 0.3 to 40 m/s
Sound Velocity ±0.2% o.r. -
Operating Ranges
Parameter Range
Gas Measuring Range 0.3 m/s to 40 m/s
Medium Temperature -50 to 150 °C (-58 to +302°F)
Medium Temperature (with pressure cell) -50 to 100 °C (-58 to +212°F)
Process Pressure 0.7 to 101 bar a (10.15 to 1464.88 psi a)
Ambient Temperature -40 to 60 °C (-40 to +140 °F)
Nominal Diameter Range
DN 25 to 300 (1 to 12")
Measured Variables
Volume flow, corrected volume flow, mass flow, flow velocity, speed of sound, pressure, temperature, density, dynamic viscosity, energy flow, Wobbe index, methane fraction, calorific value, molar mass
Construction Materials
Component Material
Measuring Tube 1.4408/1.4409 (CF3M)
Transducer 1.4404 (316, 316L, Titan Grade 2)
Sensor Housing Stainless Steel, 1.4404 (316/316L), 1.4408/1.4409 (CF3M)
Transmitter Housing AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate
Electrical & Communication
Outputs
4 outputs: 4-20 mA HART (active/passive), 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Double pulse output (active/passive), Relay output
Inputs
Status input, 4-20 mA input
Digital Communication
HART, Modbus RS485
Power Supply
AC 100 to 230 V / DC 24 V (non-hazardous area)
Certifications & Approvals
  • Hazardous Area: ATEX, IECEx, cCSAus, JPN, EAC, UK Ex, KC
  • Product Safety: CE, C-tick
  • Functional Safety: IEC 61508, applicable in safety-relevant applications per IEC 61511
  • Metrological: Calibration performed on accredited facilities (ISO/IEC 17025), Heartbeat Technology complies with ISO 9001:2015
  • Pressure: PED, CRN
  • Material: 3.1 material certificate, NACE MR0175/MR0103
Environmental Protection
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, Type 4X enclosure
Display & Operation
4-line backlit display with Touch Control (operation from outside)
Configuration via local display and operating tools possible